Operation: Electro-mechanical. Works against a standard closer. Seven second cycle time. Adjustable Timed Hold Open feature for 0 to 30 seconds, or a hold open that requires a signal to close. |
Physical application: Jamb-mount, or inverted mount; no physical attachment or arm to door. Door mount; attached to door with arm pushing against door frame header. |
Power: Requires 115vac 60hz 3amp service to receptacle box |
Material/Finish: Painted welded steel frame. ABS plastic housing. Beige or Bronze. |
Motor: 115vac 60hz permanent split capacitor, thermally protected |
Activation: Touch plate, push button, push plate, radio transmitter, mats, or any momentary dry contact signal. Wired or Wireless. |
Dimensions: 18 1/2" x 8 1/2" x 7" |
Weight: 19 pounds |
Specification for PAC Jam Mount Door Openers:
Provide Power Access Model 4300 Series door opener, shall comply with ANSI A156.19-2002, "Standard For Power Assist and Low Energy Power Operated Doors." Automatic door opener shall be electro-mechanical, self contained and mounted to the push side of jamb. The door operator wheeled arm shall not be attached to the door, so that the door may be used in the manual mode as required. The arm shall be driven by a ball screw actuator and take 7 seconds to open (and 7 seconds to close) this speed to accommodate slower moving disabled traffic. The door opener shall have an adjustable sensitivity control so the door will stop if it meets an obstruction during the opening cycle and then recycle closed. The door opener shall have an external on/off switch and an adjustable timed hold open feature from 0 30 seconds. It shall have an externally accessible circuit breaker to allow resetting in the event of an overload surge. It shall have a built-in line filter to suppress ac line transients and RFI. Door operator requires 115 vac 60 Hz 3 amp service at header location. Door operators shall have a powder painted welded steel frame, fire retardant acrylic/PVC thermoplastic cover (meets UL 94V-0). (Available in beige or dark bronze.)
The door operator shall be mounted according to drawings and instructions provided with each door opener, and used in conjunction with a conventional manual door closer, either of the surface mounted or concealed type. The closer controls the door when it is opened manually and when ever it is closing. Opener shall be compatible with wired or wireless remote controls and with electric strikes.
Specification for PAC Door Mount Door Opener:
Provide Power Access Model 4300 Series door opener, shall comply with ANSI A156.19-2002, "Standard For Power Assist and Low Energy Power Operated Doors." Automatic door opener shall be electro-mechanical, self contained and mounted to the pull side of the door. The door operator wheeled arm shall be lined up with the header of the door frame, so that the door may be used in the manual mode as required. The arm shall be driven by a ball screw actuator and take 7 seconds to open (and 7 seconds to close) this speed to accommodate slower moving disabled traffic. Clearance behind the opened door must be at least 8 ¸" to permit a full 90 degree opening of the door. The door opener shall have an adjustable sensitivity control so the door will stop if it meets an obstruction during the opening cycle and then recycle closed. The door opener shall have and external on/off switch and an adjustable timed hold open feature from 0 30 seconds. . It shall have an externally accessible circuit breaker to allow resetting in the event of an overload surge. It shall have a built-in line filter to suppress ac line transients and RFI. Door operator requires 115 vac 60 Hz 3 amp service at header location.Door operators shall have a powder painted welded steel frame, fire retardant acrylic/PVC thermoplastic cover (meets UL 94V-0). (Available in beige or dark bronze.)
The door operator shall be mounted according to drawings and instructions provided with each door opener, and used in conjunction with a conventional manual door closer, either of the surface mounted or concealed type. The closer controls the door when it is opened manually and when ever it is closing. Opener shall be compatible with wired or wireless remote controls and with electric strikes.
View the entire booklet as a web page
-or-
download/open an Adobe PDF version:
Detail drawings of various applications:
- Model 4300 DL Door Mount Opener Left Hand Beige or Bronze
- Model 4300 DR Door Mount Opener Right Hand Beige or Bronze
- Model 4300L Jamb Mount Opener Left Hand Standard Reveal Beige or Bronze
- Model 4300L-SRB Jamb Mount Opener Left Hand Shallow Reveal Beige or Bronze
- Model 4300R Jamb Mount Opener Right Hand Standard Reveal Beige or Bronze
- Model 4300R-SRB Jamb Mount Opener Right Hand Shallow Reveal Beige or Bronze
- Model 4300VL Jamb Mount Opener Left Hand Inverted Beige or Bronze
- Model 4300VR Jamb Mount Opener Right Hand Inverted Beige or Bronze
- Model 4300XL Jamb Mount Opener Left Hand Deep Reveal Beige or Bronze
- Model 4300XR Jamb Mount Opener Right Hand Deep Reveal Beige or Bronze
Electrical Detail: